Hydro-optic water disinfection
23 April, 2008 | EIMCO Water Technologies Pty Ltd
The Atlantium out-of-the-water UV disinfection system is suitable for the treatment of water and wastewater used in industrial and municipal processes. The chemical-free process uses hydro-optic disinfection (HOD) technology and is designed to replace traditional disinfection methods such as chlorine, ozone and pasteurisation.
iSeries gas analyser
23 April, 2008 | Lear Siegler Australasia Pty Ltd
Thermo Scientific's line of iSeries analysers is claimed to have the least requirement for maintenance of any analyser on the market.
Waste receiving unit
25 March, 2008 | Pump Systems Ltd
The Lackeby Products receiving unit is used for receiving, homogenisation and further transport of household and processing waste material. The unit is user designed to suit the type of received waste material and vehicles that deliver the material.
Environmental data management systems
24 March, 2008 | Lear Siegler Australasia Pty Ltd
The Envitech PC-based Environmental Data Acquisition System is available as EnviDAS and EnviDAS for Windows.
Photoelectric sensors
24 March, 2008 | ifm efector pty ltd
The ifm electronic opto family now includes the O4 series, a photoelectric sensor with ranges up to 50 m.
High-accuracy flowmeter
24 March, 2008 | Endress+Hauser Australia Pty Ltd
The latest release of the Promass F Coriolis mass flowmeter offers accuracy and reliability, making it suitable for use in most process industries.
Signal isolator
24 March, 2008 | Innovec Controls Pty Ltd
The ISCX1 is a signal isolator that accepts a 4-20 mA with an input impedance of 50W or 0-10 VDC with an input impedance of 1 MW and provides an isolated output signal of 4-20 mA or 0-10 VDC with an accuracy of 0.1%. The standard instrument provides three-way galvanic isolation with a minimum of 500 VDC from the input signal to the output signal as well as power supply isolation. The output is completely independent and can be scaled for different applications. Final calibration is achieved using the front-of-instrument, accessible, 15-turn, zero and span potentiometers.
Padlock station
24 March, 2008 | Brady Australia Pty Ltd
The Ready Access padlock stations hold up to 10 padlocks, 6 hasps and 10 tags and ensure that lockout devices remain easily accessible and ready for use whenever needed. The stations are compact (177 x 336 x 63.5 mm) and the semi-transparent hinged cover allows the contents to be viewed at a glance while protecting the lockout devices from exposure to harsh environments.
Particle counter
24 March, 2008 | STAUFF Corporation Pty Ltd
The Stauff Laser Particle Counter 1 (LasPaC1) is a microprocessor-controlled, 8-channel particle counter designed for monitoring the degree of contamination of mineral-based hydraulic fluids.
Laser particle monitors
24 March, 2008 | STAUFF Corporation Pty Ltd
The Stauff Laser Particle Monitoring, LPM 1 is a laser-based, four-channel, inline particle monitor designed for the continuous monitoring of particle contamination. The unit provides cumulative particle concentration information at >4 µm (c), >6 µm (c) and >14 µm (c) sizes applicable to the ISO 4406, ISO 11943 and ISO 11171 requirements for optical particle counters. A >21 µm (c) channel is also provided for larger particle concentration information. Machine operators are alerted to changes in particle contamination levels in a machine's fluid by the indications provided from the unit. The contamination level will be shown on the display or can be transmitted via the RS232 serial port into a personal computer. Also with the Modbus-serial port, the data can be transferred into a computer network or to an external display.
Green paper guide
24 March, 2008 | Finsbury Green Printing & Print Management
Finsbury Green has released its Green Paper Guide which is designed to help Australian businesses select an environmentally preferable paper. The guide points out it is not simply just about recycled paper - it includes other factors such as what fibres were used to make the paper stock, which forests the raw materials came from and what environmental certifications were followed in the process of making the paper.
Pressure transmitter
24 March, 2008 | Burkert Fluid Control Systems
The fixed-range Type 8314 pressure transmitter uses a ceramic technology relative pressure measurement principle. The unit is compact and stable, is stainless steel bodied and has IP67 protection class. Offering a ¼" external process connection and M12 electrical connection, the unit is available with two-wire 4-20 mA output signal.
Pneumatic focusing gas chromatography
25 February, 2008 | Lear Siegler Australasia Pty Ltd
VOC Technologies has introduced the technique of pneumatic focusing gas chromatography (PFGC). It is a continuous speciated monitor for volatile organic compounds (VOCs) and hazardous air pollutants (HAPs).
Waste management software
25 February, 2008 | ASP Software
The web-based software Test-Drive is ready to try online at Wastedge.com. It claims to make job management easier and more efficient.
Portable gas detectors
25 February, 2008 | Sensor Technologies Pty Ltd
The Impact portable gas detector is the latest generation of Neotronics gas detectors, which allows fixed-cost servicing, ease of calibration without the need for a dedicated computer or system of gas regulators and command modules.