Submersible fluorometer
23 April, 2008 | Aqualab Scientific Pty Ltd
Cyclops-7 is the latest submersible fluorometer release from Turner Designs. It measures chlorophyll a or Rhodamine WT and has an optional solid secondary standard.
Waste receiving unit
25 March, 2008 | Pump Systems Ltd
The Lackeby Products receiving unit is used for receiving, homogenisation and further transport of household and processing waste material. The unit is user designed to suit the type of received waste material and vehicles that deliver the material.
High-accuracy flowmeter
24 March, 2008 | Endress+Hauser Australia Pty Ltd
The latest release of the Promass F Coriolis mass flowmeter offers accuracy and reliability, making it suitable for use in most process industries.
Particle counter
24 March, 2008 | STAUFF Corporation Pty Ltd
The Stauff Laser Particle Counter 1 (LasPaC1) is a microprocessor-controlled, 8-channel particle counter designed for monitoring the degree of contamination of mineral-based hydraulic fluids.
Environmental data management systems
24 March, 2008 | Lear Siegler Australasia Pty Ltd
The Envitech PC-based Environmental Data Acquisition System is available as EnviDAS and EnviDAS for Windows.
Signal isolator
24 March, 2008 | Innovec Controls Pty Ltd
The ISCX1 is a signal isolator that accepts a 4-20 mA with an input impedance of 50W or 0-10 VDC with an input impedance of 1 MW and provides an isolated output signal of 4-20 mA or 0-10 VDC with an accuracy of 0.1%. The standard instrument provides three-way galvanic isolation with a minimum of 500 VDC from the input signal to the output signal as well as power supply isolation. The output is completely independent and can be scaled for different applications. Final calibration is achieved using the front-of-instrument, accessible, 15-turn, zero and span potentiometers.
Photoelectric sensors
24 March, 2008 | ifm efector pty ltd
The ifm electronic opto family now includes the O4 series, a photoelectric sensor with ranges up to 50 m.
Padlock station
24 March, 2008 | Brady Australia Pty Ltd
The Ready Access padlock stations hold up to 10 padlocks, 6 hasps and 10 tags and ensure that lockout devices remain easily accessible and ready for use whenever needed. The stations are compact (177 x 336 x 63.5 mm) and the semi-transparent hinged cover allows the contents to be viewed at a glance while protecting the lockout devices from exposure to harsh environments.
Laser particle monitors
24 March, 2008 | STAUFF Corporation Pty Ltd
The Stauff Laser Particle Monitoring, LPM 1 is a laser-based, four-channel, inline particle monitor designed for the continuous monitoring of particle contamination. The unit provides cumulative particle concentration information at >4 µm (c), >6 µm (c) and >14 µm (c) sizes applicable to the ISO 4406, ISO 11943 and ISO 11171 requirements for optical particle counters. A >21 µm (c) channel is also provided for larger particle concentration information. Machine operators are alerted to changes in particle contamination levels in a machine's fluid by the indications provided from the unit. The contamination level will be shown on the display or can be transmitted via the RS232 serial port into a personal computer. Also with the Modbus-serial port, the data can be transferred into a computer network or to an external display.
Green paper guide
24 March, 2008 | Finsbury Green Printing & Print Management
Finsbury Green has released its Green Paper Guide which is designed to help Australian businesses select an environmentally preferable paper. The guide points out it is not simply just about recycled paper - it includes other factors such as what fibres were used to make the paper stock, which forests the raw materials came from and what environmental certifications were followed in the process of making the paper.
Pressure transmitter
24 March, 2008 | Burkert Fluid Control Systems
The fixed-range Type 8314 pressure transmitter uses a ceramic technology relative pressure measurement principle. The unit is compact and stable, is stainless steel bodied and has IP67 protection class. Offering a ¼" external process connection and M12 electrical connection, the unit is available with two-wire 4-20 mA output signal.
Strap chopper
25 February, 2008 | Fromm Packaging Australia
The model 510 Sweed Strap Chopper operates at high volume and is designed to reduce PET strap into a saleable waste for recycling. The strap waste can be easily reduced in volume from a 3 m2 industrial bin to a 200 L drum.
Oxygen analyser
25 February, 2008 | Novatech Controls Pty Ltd
The 1630 oxygen analyser has been redesigned to take advantage of advances in solid-state electronics. The new series 1730 has a greater range of features while still retaining its ease of use.
MG140 gas monitor
25 February, 2008 | Air Met Scientific Pty Ltd
The MG140 is a low-cost gas monitoring solution designed for use in applications where the flexibility of a full-featured multi-gas monitor is not required.
Heavy-duty bin lifter
25 February, 2008 | Wastech Engineering Pty Ltd
The Liftezy is a heavy-duty bin lifter for lifting and tipping of all MGB bin sizes.